Users can monitor the operating status and fault conditions of key hardware components of the switch (power supply, fan, main system) through LED indicators of different colors and states.

OperationStatusDescription
:inlineImage{src="/media/archbee/sj3UGdM9O6cdovp2mAJ7x_.gif" alt caption}Yellow-green light, always onThe switch is powered on.
Not brightNot powered
SYellow-green light, always onThe system is operating normally.
Yellow-green light, flashingSystem starting up
Red light, always onHardware failure detected
Not brightNot powered
PYellow-green light, always onPSU power supply is normal
Red light, always onThere is an abnormality in the PSU
Not brightNot powered
FYellow-green light, always onAll fans are working properly.
Red light, always onFan failure
Not brightNot powered
LBlue light, flickeringEnable the device positioning indication function in the management system settings
Not brightFunction not enabled (default state)

Users can control the positioning indicator light of the switch to flash through the command line, enabling quick physical location of a specific switch among numerous devices.

Terminal window
sonic# configure
sonic(config)# led loc
LOC LED is set to: on
sonic(config)# no led loc
LOC LED is set to: off

Business Interface

OperationStatusDescription
SFP+Yellow-green light, always onThe link is connected, but there is no data transmission.
Yellow-green light, flashingThe link is connected, and there is data transmission.
Not brightLink disconnected
QSFP28 or laterGreen light, always onThe link is connected, but there is no data transmission.
Green light, flashingThe link is connected, and there is data transmission.
Not brightLink disconnected
RJ45Orange light, always onThe link is connected, but there is no data transmission.
Orange light, flickeringThe link is connected, and there is data transmission.
Not brightLink disconnected
RJ45 PoE(right side)Yellow-green light, always onThe POE interface is supplying power normally.
Not brightNo power supply

Out-of-band management port

OperationCommandDescription
PWR/RUNOrange light, always onThe system is starting up or there is a startup abnormality
Yellow-green light, slow flashing (0.5Hz frequency)The system is working properly.
The orange light and the yellow-green light flash alternately (2Hz frequency)Hardware failure detected, such as excessive device temperature and abnormal fan operation.
Orange light, fast flashing (8Hz frequency)The system is in an over-temperature protection state (global reset) and has triggered the over-temperature protection threshold.
LINK / ACTYellow-green light, always onThe link is connected, but there is no data transmission.
Yellow-green light, flashingThe link is connected, and there is data transmission.
Not brightLink disconnected
GIGAYellow-green light, always on1000M link, connected, no data transmission
Yellow-green light, flashing1000M link, connected, with data transmission
Not brightThe link is disconnected or it is a 10M/100M link

Operations staff need to quickly grasp the key hardware health status of switches during daily inspections or hardware fault troubleshooting. The “show environment” command provides the ability to view all key hardware operating indicators in one stop, eliminating the need for item-by-item checks.

CommandDescription
show environment allFan speed, temperature of various parts, power supply status, and system hardware information
show environment fansReal-time rotational speed (RPM) of all fans
show environment tempsTemperatures of key components such as CPU, switch chips, and fans
show environment powersInput/output voltage, current, power, temperature, and fan speed of the power supply unit (PSU)
show environment systemSystem hardware information, such as CPLD and motherboard versions

The status and summary information of the hardware platform itself can also be obtained through the show platform command.

OperationCommandDescription
Check the fan statusshow platform fanSpeed : Rotational speed (RPM)
Direction : Wind direction (exhaust: outward / inhaust: inward)
Presence : In-position state
Status : Working status (OK means normal)
Timestamp : Status update time
Check the status of the power moduleshow platform psu-statusStatus
OK : In position and with normal power supply
NOT OK : In position but not powered
NOT PRESENT : The power module is not in place
Check the temperature of each part of the deviceshow platform temperatureNAME : Component names (CPU, FAN, SWITCH)
Temperature
High/Low Threshold: High/low temperature alarm threshold
Critical High/Low Threshold : Severe high/low temperature alarm thresholds
Warning Status : Warning status (true indicates exceeding the threshold)
Timestamp : The time when this temperature was recorded
Check the hardware platform summary informationshow platform summaryPlatform : Hardware platform model
Device : Device model
ASIC : Switch chip model
View detailed information about the hardware platformshow platform sys-eepromProduct Name
Part Number
Serial Number : Device serial number (key for License generation)
Base MAC Address
Manufacture Date
Device Version
Platform Name : Hardware platform model
ONIE Version : ONIE boot environment version
Manufacturer
Manufacture Country
Switch Vendor
Main Board Version
Board2 Version : PoE module model (display “none” if not installed)
Board4 Version : PTP module model (displays “none” if not installed)